PP impact copolymer, MFR 4–5: J440N vs BJ300 vs 36MK10R vs EP300L vs B300KG
Low-flow PP impact copolymer (MFR 4–5) is used for large, thick injection parts that must take impact: crates, boxes, chairs and technical parts. The five grades below come from five producers.
Updated: 17 Nov 2026 · Thien An Plastics
TDS comparison
| Property | J440N Hyosung (Topilene) | BJ300 Hanwha TotalEnergies | 36MK10R SABIC | EP300L Polymirae (Ulsan PP) | B300KG PETRONAS |
|---|---|---|---|---|---|
| Melt flow (230 °C/2.16 kg) | 4 g/10 min | 5 g/10 min | 5.5 g/10 min | 5 g/10 min | 4 g/10 min |
| Density | 0.9 g/cm³ | 0.91 g/cm³ | — | 0.9 g/cm³ | — |
| Tensile strength at yield | 280 kg/cm² (≈27.5 MPa) | 290 kg/cm² (≈28.4 MPa) | 25 MPa | — | 27 MPa |
| Flexural modulus | 13500 kg/cm² (≈1,324 MPa) | 13000 kg/cm² (≈1,275 MPa) | 1170 MPa | — | — |
| Notched Izod impact (23 °C) | 12 kg·cm/cm (≈118 J/m) | 12 kg·cm/cm (≈118 J/m) | 10 kJ/m² | — | — |
| HDT (0.45 MPa) | 105 °C | 110 °C | 106 °C | — | — |
| Vicat softening point | — | — | 154 °C | 150 °C | — |
| Rockwell hardness (R) | — | — | — | 90 | — |
| Notched Charpy impact (23 °C) | — | — | — | — | 13 kJ/m² |
Typical values from each producer's TDS, for reference only, not guaranteed specifications. "—" means not stated on the TDS. Values marked "≈" are unit conversions by Thien An for easier comparison.
Key differences
- J440N (Hyosung) and BJ300 (Hanwha TotalEnergies) are almost equivalent: flexural modulus ≈1,320 and ≈1,275 MPa, Izod ≈118 J/m, HDT 105 and 110 °C.
- 36MK10R (SABIC) reports Izod as 10 kJ/m² (ISO units) and Vicat 154 °C; B300KG (PETRONAS) reports Charpy 13 kJ/m² – different units and methods, not directly comparable with J440N and BJ300.
- The EP300L (Polymirae) TDS states only Rockwell R90 and Vicat 150 °C.
- Low MFR gives tough, impact-resistant parts but needs higher injection pressure and temperature.
Which grade to choose?
- Running J440N or BJ300: the other is the closest substitute.
- Need more heat resistance: BJ300 (HDT 110 °C) or 36MK10R (Vicat 154 °C).
- Switching to 36MK10R, EP300L or B300KG: run real impact tests, as their TDS use different methods.
Tips when switching grades
- Compare like with like: same test method and units (ISO/ASTM; MPa or kg/cm²; Izod or Charpy). Values from different methods are not directly comparable.
- Melt flow has a lot-to-lot tolerance – check the COA of the actual lot, not just the TDS.
- Different additives (nucleating, antistatic, antioxidant, slip) can change the part even when key values match.
- Always trial on your own machine and mold: check temperature, pressure, shrinkage, colour and appearance before switching volume.
FAQ
Can J440N and BJ300 replace each other?
Per TDS their MFR, modulus, impact and HDT are very close, so usually yes; trial the first lot.
Can 10 kJ/m² and 118 J/m be compared?
No. kJ/m² (ISO) divides energy by specimen area, J/m (ASTM) by thickness; specimens and methods differ, so there is no direct conversion.
What is MFR 4–5 PP used for?
Large, thick injection parts needing impact strength, such as crates, boxes, chairs and technical parts.
Grade pages with TDS downloads: J440N · BJ300 · 36MK10R · EP300L · B300KG
Other comparisons: LDPE film grades · LLDPE film grades · HDPE film grades · HDPE injection grades by melt flow · HDPE pipe grades · HDPE for large blow-molded parts
Based on producers' public TDS, for technical reference only. For grade advice or a quote, contact Thien An Plastics: +84 389 980 742 (WhatsApp, WeChat, Zalo).